Goodman and Amana furnace error codes offer essential insights into device performance, aiding swift and effective issue identification.
Codes List
- on: Normal operation
- a: Indicates airflow, followed by cfm
- b0: Blower motor not running
- b1: Blower communication error
- b2: Blower hp mis-match
- b3: Blower motor operating in power, temperature, or speed limit
- b4: Blower motor current trip or lost rotor
- b5: Blower motor locked rotor
- b6: Blower over/under voltage trip or over temperature trip
- b7: Incomplete parameters sent to motor
- b9: Low indoor airflow
- c: Climatetalk compressor cooling / conventional compressor cooling when 1-stage compressor is set up
- c1: Low stage cool
- c2: High stage cool
- d: Climatetalk compressor cooling with dehumification / conventional compressor cooling with dehumidification when 1-stage compressor is set up
- d0: Data not yet on network
- d1: Conventional 1-stage compressor cooling with dehumidification when 2-stage compressor is set up
- d2: Conventional 2-stage compressor cooling with dehumidification when 2-stage compressor is set up
- d4: Invalid memory card data
- df: Defrost demand
- e0: Lockout due to excessive retries or recycles
- e1: Low stage pressure switch stuck closed at start of heating cycle
- e2: Low stage pressure switch stuck open
- e3: Open high limit switch
- e4: Flame detected when no flame should be present
- e5: Open fuse
- e6: Low flame signal
- e7: Igniter fault or improper grounding
- e8: High stage pressure switch stuck closed at start of heating cycle
- e9: High stage pressure switch stuck open
- ea: Reversed 115 vac polarity
- ec: Inducer motor overcurrent fault
- ed: Rollout switch open
- ef: Auxiliary input open
- f: Continuous fan
- ft: Field test mode
- h: Indicates gas heat, followed by percentage of demand
- hi: High heat = 100%
- if: Internal fault
- p: Climatetalk compressor heating / conventional compressor heating when 1-stage compressor is set up
- p1: Conventional 1-stage compressor heating when 2-stage compessor is set up
- p2: Conventional 2-stage compressor heating when 2-stage compessor is set u
- 50: % Off high heat
Fault Code Reset
To clear the fault code memory, push and hold the “LAST ERROR” button for more than 5 seconds and less than 10 seconds (the LED will indicate this period by RAPID GREEN FLASH for 5 seconds to 10 seconds). The LED will flash three green flashes when the memory has been cleared.
The ignition control is equipped with a momentary push button switch that can be used to display on the diagnostic LED the last five faults detected by the control. The control must be in Standby Mode (no thermostat inputs) to use the feature.
Depress the push button switch for approximately 2 seconds. Release the switch when the LED is turned off. The diagnostic LED will then display the flash codes associated with the last five detected faults. The order of display is the most recent fault to the least recent fault.
Led Status Flashing
Error and Condition
Manual Pdf
Installation Instructions for MES9 and CES9 Single-Stage Gas Furnace